@ -0,0 +1,81 @@
|
||||
Pause Frame Mode: none
|
||||
driver: net_e1000_igb
|
||||
version: 1.6
|
||||
firmware-version:
|
||||
expansion-rom-version:
|
||||
bus-info: 0000:01:00.0
|
||||
supports-statistics: no
|
||||
supports-test: no
|
||||
supports-eeprom-access: no
|
||||
supports-register-dump: no
|
||||
supports-priv-flags: no
|
||||
EEPROM - ID
|
||||
Connector : LC
|
||||
Vendor Manufacturing date : 2018-03-22
|
||||
Diagnostic Monitoring Type : 0x68
|
||||
Encoding : 8B/10B
|
||||
Transceiver : BASE-BX10
|
||||
Extended Identifier :
|
||||
Identifier : SFP/SFP+/SFP28
|
||||
Nominal Bit Rate : 1300 Mbps
|
||||
Vendor Serial Number : BT20180322002
|
||||
SFF-8472 Compliance : SFF_8472 rev 9.3
|
||||
SFP vendor name : CISCO
|
||||
Vendor OUI : 00.00.00
|
||||
Vendor Part Number : BT-OC24-20A
|
||||
Vendor Revision Level : A0
|
||||
Copper/direct attach link length : 0
|
||||
50um OM3 fiber link length : 0
|
||||
Single mode fiber link length : 200
|
||||
Single mode fiber link length : 20
|
||||
50um OM2 fiber link length : 0
|
||||
62.5um OM1 fiber link length : 0
|
||||
EEPROM - Diagnostics
|
||||
Thresholds
|
||||
High rx power alarm threshold : 0.0000 dBm
|
||||
High rx power warning threshold : -1.0002 dBm
|
||||
Low rx power alarm threshold : -36.9897 dBm
|
||||
Low rx power warning threshold : -33.0103 dBm
|
||||
High tx power alarm threshold : 1.9997 dBm
|
||||
High tx power warning threshold : 0.9999 dBm
|
||||
Low tx power alarm threshold : -12.1112 dBm
|
||||
Low tx power warning threshold : -11.0018 dBm
|
||||
High temperature alarm threshold : 90 degrees C
|
||||
High temperature warning threshold : 80 degrees C
|
||||
Low temperature alarm threshold : -30 degrees C
|
||||
Low temperature warning threshold : -25 degrees C
|
||||
High voltage alarm threshold : 3 V
|
||||
High voltage warning threshold : 3 V
|
||||
Low voltage alarm threshold : 2 V
|
||||
Low voltage warning threshold : 2 V
|
||||
High laser bias alarm threshold : 75 mA
|
||||
High laser bias warning threshold : 70 mA
|
||||
Low laser bias alarm threshold : 3 mA
|
||||
Low laser bias warning threshold : 5 mA
|
||||
Measured values
|
||||
Rx power : -10.9420 dBm
|
||||
Laser Tx Bias : 22 mA
|
||||
Tx power : -4.9675 dBm
|
||||
Temperature : 36 degrees C
|
||||
Voltage : 3 V
|
||||
Alarm and warning flags
|
||||
High temperature alarm : OFF
|
||||
Low temperature alarm : OFF
|
||||
High voltage alarm : OFF
|
||||
Low voltage alarm : OFF
|
||||
High temperature warning : OFF
|
||||
Low temperature warning : OFF
|
||||
High voltage warning : OFF
|
||||
Low voltage warning : OFF
|
||||
High tx bias alarm : OFF
|
||||
Low tx bias alarm : OFF
|
||||
High rx power alarm : OFF
|
||||
Low rx power alarm : OFF
|
||||
High tx power alarm : OFF
|
||||
Low tx power alarm : OFF
|
||||
High tx bias warning : OFF
|
||||
Low tx bias warning : OFF
|
||||
High rx power warning : OFF
|
||||
Low rx power warning : OFF
|
||||
High tx power warning : OFF
|
||||
Low tx power warning : OFF
|
Reference in New Issue