Pause Frame Mode: none
driver: net_e1000_igb
version: 1.6
firmware-version: 
expansion-rom-version: 
bus-info: 0000:01:00.0
supports-statistics: no
supports-test: no
supports-eeprom-access: no
supports-register-dump: no
supports-priv-flags: no
EEPROM - ID
  Connector                                   : LC
  Vendor Manufacturing date                   : 2018-03-22
  Diagnostic Monitoring Type                  : 0x68
  Encoding                                    : 8B/10B
  Transceiver                                 : BASE-BX10
  Extended Identifier                         :  
  Identifier                                  : SFP/SFP+/SFP28
  Nominal Bit Rate                            : 1300 Mbps
  Vendor Serial Number                        : BT20180322002
  SFF-8472 Compliance                         : SFF_8472 rev 9.3
  SFP vendor name                             : CISCO
  Vendor OUI                                  : 00.00.00
  Vendor Part Number                          : BT-OC24-20A
  Vendor Revision Level                       : A0
  Copper/direct attach link length            : 0
  50um OM3 fiber link length                  : 0
  Single mode fiber link length               : 200
  Single mode fiber link length               : 20
  50um OM2 fiber link length                  : 0
  62.5um OM1 fiber link length                : 0
EEPROM - Diagnostics
  Thresholds
    High rx power alarm threshold             : 0.0000 dBm
    High rx power warning threshold           : -1.0002 dBm
    Low  rx power alarm threshold             : -36.9897 dBm
    Low  rx power warning threshold           : -33.0103 dBm
    High tx power alarm threshold             : 1.9997 dBm
    High tx power warning threshold           : 0.9999 dBm
    Low  tx power alarm threshold             : -12.1112 dBm
    Low  tx power warning threshold           : -11.0018 dBm
    High temperature alarm threshold          : 90 degrees C
    High temperature warning threshold        : 80 degrees C
    Low  temperature alarm threshold          : -30 degrees C
    Low  temperature warning threshold        : -25 degrees C
    High voltage alarm threshold              : 3 V
    High voltage warning threshold            : 3 V
    Low  voltage alarm threshold              : 2 V
    Low  voltage warning threshold            : 2 V
    High laser bias alarm threshold           : 75 mA
    High laser bias warning threshold         : 70 mA
    Low  laser bias alarm threshold           : 3 mA
    Low  laser bias warning threshold         : 5 mA
  Measured values
    Rx power                                  : -10.9420 dBm
    Laser Tx Bias                             : 22 mA
    Tx power                                  : -4.9675 dBm
    Temperature                               : 36 degrees C
    Voltage                                   : 3 V
  Alarm and warning flags
    High temperature alarm                    : OFF
    Low  temperature alarm                    : OFF
    High voltage alarm                        : OFF
    Low  voltage alarm                        : OFF
    High temperature warning                  : OFF
    Low  temperature warning                  : OFF
    High voltage warning                      : OFF
    Low  voltage warning                      : OFF
    High tx bias alarm                        : OFF
    Low  tx bias alarm                        : OFF
    High rx power alarm                       : OFF
    Low  rx power alarm                       : OFF
    High tx power alarm                       : OFF
    Low  tx power alarm                       : OFF
    High tx bias warning                      : OFF
    Low  tx bias warning                      : OFF
    High rx power warning                     : OFF
    Low  rx power warning                     : OFF
    High tx power warning                     : OFF
    Low  tx power warning                     : OFF