Pause Frame Mode: none
driver: net_e1000_igb
version: 1.6
firmware-version:
expansion-rom-version:
bus-info: 0000:01:00.0
supports-statistics: no
supports-test: no
supports-eeprom-access: no
supports-register-dump: no
supports-priv-flags: no
EEPROM - ID
Connector : LC
Vendor Manufacturing date : 2018-03-22
Diagnostic Monitoring Type : 0x68
Encoding : 8B/10B
Transceiver : BASE-BX10
Extended Identifier :
Identifier : SFP/SFP+/SFP28
Nominal Bit Rate : 1300 Mbps
Vendor Serial Number : BT20180322305
SFF-8472 Compliance : SFF_8472 rev 9.3
SFP vendor name : CISCO
Vendor OUI : 00.00.00
Vendor Part Number : SFP-GE-BX
Vendor Revision Level : A0
Copper/direct attach link length : 0
50um OM3 fiber link length : 0
Single mode fiber link length : 100
Single mode fiber link length : 10
50um OM2 fiber link length : 0
62.5um OM1 fiber link length : 0
EEPROM - Diagnostics
Thresholds
High rx power alarm threshold : 0.0000 dBm
High rx power warning threshold : -1.0002 dBm
Low rx power alarm threshold : -36.9897 dBm
Low rx power warning threshold : -33.0103 dBm
High tx power alarm threshold : 1.9997 dBm
High tx power warning threshold : 0.9999 dBm
Low tx power alarm threshold : -12.1112 dBm
Low tx power warning threshold : -11.0018 dBm
High temperature alarm threshold : 90 degrees C
High temperature warning threshold : 80 degrees C
Low temperature alarm threshold : -30 degrees C
Low temperature warning threshold : -25 degrees C
High voltage alarm threshold : 3 V
High voltage warning threshold : 3 V
Low voltage alarm threshold : 2 V
Low voltage warning threshold : 2 V
High laser bias alarm threshold : 75 mA
High laser bias warning threshold : 70 mA
Low laser bias alarm threshold : 3 mA
Low laser bias warning threshold : 5 mA
Measured values
Rx power : -10.6854 dBm
Laser Tx Bias : 23 mA
Tx power : -5.2244 dBm
Temperature : 31 degrees C
Voltage : 3 V
Alarm and warning flags
High temperature alarm : OFF
Low temperature alarm : OFF
High voltage alarm : OFF
Low voltage alarm : OFF
High temperature warning : OFF
Low temperature warning : OFF
High voltage warning : OFF
Low voltage warning : OFF
High tx bias alarm : OFF
Low tx bias alarm : OFF
High rx power alarm : OFF
Low rx power alarm : OFF
High tx power alarm : OFF
Low tx power alarm : OFF
High tx bias warning : OFF
Low tx bias warning : OFF
High rx power warning : OFF
Low rx power warning : OFF
High tx power warning : OFF
Low tx power warning : OFF