Always set interface up after MTU change; otherwise only set it up if it was down
This commit is contained in:
@ -740,13 +740,13 @@ class Reconciler():
|
|||||||
if bond.members == 0 and member_iface.l2_address != bondmac:
|
if bond.members == 0 and member_iface.l2_address != bondmac:
|
||||||
bondmac_changed = True
|
bondmac_changed = True
|
||||||
bondmac = member_iface.l2_address
|
bondmac = member_iface.l2_address
|
||||||
self.logger.info("2> bond add %s %s" % (vpp_ifname, member_iface.interface_name))
|
self.logger.info("1> bond add %s %s" % (vpp_ifname, member_iface.interface_name))
|
||||||
if member_iface.link_mtu != config_mtu:
|
if member_iface.link_mtu != config_mtu:
|
||||||
self.logger.info("1> set interface state %s down" % (member_iface.interface_name))
|
self.logger.info("2> set interface state %s down" % (member_iface.interface_name))
|
||||||
self.logger.info("1> set interface mtu %d %s" % (config_mtu, member_iface.interface_name))
|
self.logger.info("2> set interface mtu %d %s" % (config_mtu, member_iface.interface_name))
|
||||||
|
|
||||||
if not member_iface.flags & 1: # IF_STATUS_API_FLAG_ADMIN_UP
|
|
||||||
self.logger.info("2> set interface state %s up" % (member_iface.interface_name))
|
self.logger.info("2> set interface state %s up" % (member_iface.interface_name))
|
||||||
|
elif not member_iface.flags & 1: # IF_STATUS_API_FLAG_ADMIN_UP
|
||||||
|
self.logger.info("3> set interface state %s up" % (member_iface.interface_name))
|
||||||
if bond_iface.link_mtu < config_mtu:
|
if bond_iface.link_mtu < config_mtu:
|
||||||
self.logger.warning("%s has a Max Frame Size (%d) lower than desired MTU (%d), this is unsupported" %
|
self.logger.warning("%s has a Max Frame Size (%d) lower than desired MTU (%d), this is unsupported" %
|
||||||
(vpp_ifname, bond_iface.link_mtu, config_mtu))
|
(vpp_ifname, bond_iface.link_mtu, config_mtu))
|
||||||
@ -755,7 +755,7 @@ class Reconciler():
|
|||||||
## NOTE(pim) - VPP does not allow the link_mtu to change on a BondEthernet, so it can be the
|
## NOTE(pim) - VPP does not allow the link_mtu to change on a BondEthernet, so it can be the
|
||||||
## case that packet MTU > link_mtu if the desired MTU > 9000. This is because BondEthernets
|
## case that packet MTU > link_mtu if the desired MTU > 9000. This is because BondEthernets
|
||||||
## are always created with link_mtu 9000.
|
## are always created with link_mtu 9000.
|
||||||
self.logger.info("3> set interface mtu packet %d %s" % (config_mtu, bond_iface.interface_name))
|
self.logger.info("4> set interface mtu packet %d %s" % (config_mtu, bond_iface.interface_name))
|
||||||
|
|
||||||
config_ifname, config_iface = interface.get_by_name(self.cfg, vpp_ifname)
|
config_ifname, config_iface = interface.get_by_name(self.cfg, vpp_ifname)
|
||||||
if bondmac_changed and 'lcp' in config_iface:
|
if bondmac_changed and 'lcp' in config_iface:
|
||||||
@ -765,7 +765,7 @@ class Reconciler():
|
|||||||
## However, LinuxCP does not propagate this change to the Linux side (because there
|
## However, LinuxCP does not propagate this change to the Linux side (because there
|
||||||
## is no API callback for MAC address changes). To ensure consistency, every time we
|
## is no API callback for MAC address changes). To ensure consistency, every time we
|
||||||
## sync members, we ought to ensure the Linux device has the same MAC as its BondEthernet.
|
## sync members, we ought to ensure the Linux device has the same MAC as its BondEthernet.
|
||||||
self.logger.info("1> comment { ip link set %s address %s }" % (config_iface['lcp'], str(bondmac)))
|
self.logger.info("5> comment { ip link set %s address %s }" % (config_iface['lcp'], str(bondmac)))
|
||||||
|
|
||||||
return True
|
return True
|
||||||
|
|
||||||
|
Reference in New Issue