date: "2024-06-29T06:31:00Z"
|
|
title: 'Case Study: IPng at Coloclue'
|
|
aliases:
|
|
- /s/articles/2024/06/29/coloclue-ipng.html
|
|
---
|
|
|
|
{{< image width="250px" float="right" src="/assets/coloclue-vpp/coloclue_logo2.png" alt="Coloclue" >}}
|
|
|
|
I have been a member of the Coloclue association in Amsterdam for a long time. This is a networking
|
|
association in the social and technical sense of the word. [[Coloclue](https://coloclue.net)] is
|
|
based in Amsterdam with members throughout the Netherlands and Europe. Its goals are to facilitate
|
|
learning about and operating IP based networks and services. It has about 225 members who, together,
|
|
have built this network and deployed about 135 servers across 8 racks in 3 datacenters (Qupra,
|
|
EUNetworks and NIKHEF). Coloclue is operating [[AS8283](https://as8283.peeringdb.net/)] across
|
|
several local and international internet exchange points.
|
|
|
|
A small while ago, one of our members, Sebas, shared their setup with the membership. It generated a
|
|
bit of a show-and-tell response, with Sebas and other folks on our mailinglist curious as to how we
|
|
all deployed our stuff. My buddy Tim pinged me on Telegram: "This is something you should share for
|
|
IPng as well!", so this article is a bit different than my usual dabbles. It will be more of a show
|
|
and tell: how did I deploy and configure the _Amsterdam Chapter_ of IPng Networks?
|
|
|
|
I'll make this article a bit more picture-dense, to show the look-and-feel of the equipment.
|
|
|
|
{{< image width="350px" float="right" src="/assets/coloclue-ipng/MPLS-Amsterdam.svg" alt="MPLS Ring" >}}
|
|
|
|
### Network
|
|
|
|
One thing that Coloclue and IPng Networks have in common is that we are networking clubs :) And
|
|
readers of my articles may well know that I do so very much like writing about networking. During
|
|
the Corona Pandemic, my buddy Fred asked "Hey you have this PI /24, why don't you just announce it
|
|
yourself? It'll be fun!" -- and after resisting for a while, I finally decided to go for it. Fred
|
|
owns a Swiss ISP called [[IP-Max](https://ip-max.net/)] and he was about to expand into Amsterdam,
|
|
and in an epic roadtrip we deployed a point of presence for IPng Networks in each site where IP-Max
|
|
has a point of presence.
|
|
|
|
In Amsterdam, I introduced Fred to Arend Brouwer from [[ERITAP](https://eritap.com/)], and we
|
|
deployed our stuff in a brand new rack he had acquired at NIKHEF. It was fun to be in an AirBnB,
|
|
drive over to NIKHEF, and together with Arend move in to this completely new and empty rack in one
|
|
of the most iconic internet places on the planet. I am deeply grateful for the opportunity.
|
|
|
|
{{< image width="350px" float="right" src="/assets/coloclue-ipng/staging-ams01.png" alt="Staging" >}}
|
|
|
|
For IP-Max, this deployment means a Nexus 3068PQ switch and an ASR9001 router, with one 10G
|
|
wavelength towards Newtelco in Frankfurt, Germany, and another 10G wavelength towards ETIX in Lille,
|
|
France. For IPng it means a Centec S5612X switch, and a Supermicro router. To the right you'll see
|
|
the network as it was deployed during that roadtrip - a ring of sites from Zurich, Frankfurt,
|
|
Amsterdam, Lille, Paris, Geneva and back to Zurich. They are all identical in terms of hardware.
|
|
Pictured to the right is our _staging_ environment, in that AirBnB in Amsterdam: Fred's Nexus and
|
|
Cisco ASR9k, two of my Supermicro routers, and an APU which is used as an OOB access point.
|
|
|
|
### Hardware
|
|
|
|
Considering Coloclue is a computer and network association, lots of folks are interested in the
|
|
physical bits. I'll take some time to detail the hardware that I use for my network, focusing
|
|
specifically on the Amsterdam sites.
|
|
|
|
#### Switches
|
|
|
|
{{< image width="350px" float="right" src="/assets/coloclue-ipng/centec-stack.png" alt="Centec" >}}
|
|
|
|
My switches are from a brand called Centec. They make their own switch silicon, and are known to be
|
|
very power efficient, affordable cost per port, and what's important for me is that the switches
|
|
offer MPLS, VPLS and L2VPN, as well as VxLAN, GENEVE and GRE functionality, all in hardware.
|
|
|
|
Pictured on the right you can see two main Centec switch types that I use (in the red boxes above
|
|
called _IPng Site Local_):
|
|
* Centec S5612X: 8x1G RJ45, 8x1G SFP, 12x10G SFP+, 2x40G QSFP+ and 8x25G SFP28
|
|
* Centec S5548X: 48x1G RJ45, 2x40G QSFP+ and 4x25G SFP28
|
|
* Centec S5624X: 24x10G SFP+ and 2x100G QSFP28
|
|
|
|
There are also bigger variants, such as the S7548N-8Z switch (48x25G, 8x100G, which is delicious),
|
|
or S7800-32Z (32x100G, which is possibly even more yummy). Overall, I have very good experiences
|
|
with these switches and the vendor ecosystem around them (optics, patch cables, WDM muxes, and so
|
|
on).
|
|
|
|
Sandwidched between the switches, you'll see some black Supermicro machines with 6x1G, 2x10G SFP+
|
|
and 2x 25G SFP28. I'll detail them below, they are IPng's default choice for low-power routers, as
|
|
fully loaded they consume about 45W, and can forward 65Gbps and around 35Mpps or so, enough to
|
|
kill a horse. And definitely enough for IPng!
|
|
|
|
{{< image width="350px" float="right" src="/assets/coloclue-ipng/msw0.nlams0.png" alt="msw0.nlams0" >}}
|
|
|
|
A photo album with a few pictures of the Centec switches, including their innards, lives
|
|
[[here](https://photos.app.goo.gl/Mxzs38p355Bo4qZB6)]. In Amsterdam, I have one S5624X, which
|
|
connects with 3x10G to IP-Max (one link to Lille, another to Frankfurt, and the third for local
|
|
services off of IP-Max's ASR9001). Pictured right is that Centec S5624X MPLS switch at NIKHEF,
|
|
called `msw0.nlams0.net.ipng.ch`, which is where my Amsterdam story really begins: _"Goed zat voor
|
|
doordeweeks!"_
|
|
|
|
#### Router
|
|
|
|
{{< image width="350px" float="right" src="/assets/coloclue-ipng/nlams0-inside.png" alt="nlams0 innards" >}}
|
|
|
|
The european ring that I built on my roadtrip with Fred consists of identical routers in each
|
|
location. I was looking for a machine that has competent out of band operations with IPMI or iDRAC,
|
|
could carry 32GB of ECC memory, had at least 4C/8T, and as many 10Gig ports as could realistically
|
|
fit. I settled on the Supermicro 5018D-FN8T
|
|
[[ref](https://www.supermicro.com/en/products/system/1u/5018/sys-5018d-fn8t.cfm)], because of its
|
|
relatively low power CPU (an Intel Xeon D-1518 at 35W TDP), ability to boot off of NVME or mSATA,
|
|
PCIe v3.0 x8 expansion port, which carries an additional Intel X710-DA4 quad-tengig port.
|
|
|
|
I've loadtested these routers extensively while I was working on the Linux Control Plane in VPP, and
|
|
I can sustain full port speeds on all six TenGig ports, to a maximum of roughly 35Mpps of IPv4, IPv6
|
|
or MPLS traffic. Considering the machine, when fully loaded, will draw about 45 Watts, this is a
|
|
very affordable and power efficient router. I love them!
|
|
|
|
{{< image width="350px" float="right" src="/assets/coloclue-ipng/nlams0.png" alt="nlams0" >}}
|
|
|
|
The only one thing I'd change , is a second power supply. I personally have never had a PSU fail in
|
|
any of the Supermicro routers I operate, but sometimes datacenters do need to take a feed offline,
|
|
and that's unfortunate if it causes an interruption. If I'd do it again, I would go for dual PSU,
|
|
but I can't complain either, as my router in NIKHEF has been running since 2021 without any power
|
|
issues.
|
|
|
|
I'm a huge fan of Supermicro's IPMI design based on the ASpeed AST2400 BMC; it supports almost all
|
|
IPMI features, notably serial-over-LAN, remote port off/cycle, remote KVM over HTML5, remote USB
|
|
disk mount, remote install of operating systems, and requires no download of client software. It all
|
|
just works in Firefox or Chrome or Safari -- and I've even reinstalled several routers remotely, as
|
|
I described in my article [[Debian on IPng's VPP routers]({{< ref "2023-12-17-defra0-debian" >}})].
|
|
There's just something magical about remote-mounting a Debian Bookworm iso image from my workstation
|
|
in Brüttisellen, Switzerland, in a router running in Amsterdam, to then proceed to use KVM over
|
|
HTML5 to reinstall the whole thing remotely. We didn't have that, growing up!!
|
|
|
|
#### Hypervisors
|
|
|
|
{{< image width="350px" float="right" src="/assets/coloclue-ipng/hvn0.nlams1.png" alt="hvn0.nlams1" >}}
|
|
|
|
I host two machines at Coloclue. I started off way back in 2010 or so with one Dell R210-II. That
|
|
machine still runs today, albeit in the Telehouse2 datacenter in Paris. At the end of 2022, I made a
|
|
trip to Amsterdam to deploy three identical machines, all reasonably spec'd Dell PowerEdge R630
|
|
servers:
|
|
|
|
1. 8x32GB or 256GB Registered/Buffered (ECC) DDR4
|
|
1. 2x Intel Xeon E5-2696 v4 (88 CPU threads in total)
|
|
1. 1x LSI SAS3008 SAS12 controller
|
|
1. 2x 500G Crucial MX500 (TLC) SSD
|
|
1. 3x 3840G Seagate ST3840FM0003 (MLC) SAS12
|
|
1. Dell rNDC 2x Intel I350 (RJ45), 2x Intel X520 (10G SFP+)
|
|
|
|
{{< image width="350px" float="right" src="/assets/coloclue-ipng/R630-S5612X.png" alt="Dell+Centec" >}}
|
|
|
|
Once you go to enterprise storage, you will never want to go back. I take specific care to buy
|
|
redundant boot drives, mostly Crucial MX500 because it's TLC flash, and a bit more reliable. However,
|
|
the MLC flash from these Seagate and HPE SAS-3 drives (12Gbps bus speeds) are next level. The Seagate
|
|
3.84TB drives are in a RAIDZ1 together, and read/write over them is a sustained 2.6GB/s and roughly
|
|
380Kops/sec per drive. It really makes the VMs on the hypervisor fly -- and at the same time has a
|
|
much, much, much better durability and lifetime. Before I switched to enterprise storage, I would
|
|
physically wear out a Samsung consumer SSd in about 12-15mo, and reads/writes would become
|
|
unbearably slow over time. With these MLC based drives: no such problem. _Ga hard!_
|
|
|
|
All hypervisors run Debian Bookworm and have a dedicated iDRAC enterprise port + license. I find the
|
|
Supermicro IPMI a little bit easier to work with, but the basic features are supported on the Dell
|
|
as well: serial-over-LAN (which comes in super handy at Coloclue) and remote power on/off/cycle, power
|
|
metering (using `ipmitool sensors`), and a clunky KVM over HTML if need be.
|
|
|
|
### Coloclue: Routing
|
|
|
|
Let's dive into the Coloclue deployment, here's an overview picture, with three colors:
|
|
<span style='color:blue;font-weight:bold;'>blue</span> for Coloclue's network components,
|
|
<span style='color:red;font-weight:bold;'>red</span> for IPng's internal network, and
|
|
<span style='color:orange;font-weight:bold;'>orange</span> for IPng's public network services.
|
|
|
|
{{< image src="/assets/coloclue-ipng/AS8298-Amsterdam.svg" alt="Amsterdam" >}}
|
|
|
|
{{< image width="350px" float="right" src="/assets/coloclue-ipng/nikhef.png" alt="NIKHEF" >}}
|
|
|
|
Coloclue currently has three main locations: Qupra, EUNetworks and NIKHEF. I've drawn the Coloclue
|
|
network in <span style='color:blue;font-weight:bold;'>blue</span>. It's pretty impressive, with
|
|
a 10G wave between each of the locations. Within the two primary colocation sites (Qupra and
|
|
EUNetworks), there are two core switches from Arista, which connect to top-of-rack switches from
|
|
FS.com in an MLAG configuration. This means that each TOR is connected redundantly to both core
|
|
switches with 10G. The switch in NIKHEF connects to a set of local internet exchanges, and as well to
|
|
IP-Max, who deliver a bunch of remote IXPs toIPng'sColoclue, notably DE-CIX, FranceIX, and SwissIX. It is
|
|
in NIKHEF where `nikhef-core-1.switch.nl.coloclue.net` (colored <span
|
|
style='color:blue;font-weight:bold;'>blue</span>), connects to my my `msw0.nlams0.net.ipng.ch`
|
|
switch (in <span style='color:red;font-weight:bold;'>red</span>). IPng Networks' european backbone
|
|
then connects from here to Frankfurt and southbound onwards to Zurich, but it also connects from
|
|
here to Lille and southbound onwards to Paris.
|
|
|
|
In the picture to right you can see ERITAP's rack R181 in NIKHEF, when it was ... younger. It did
|
|
not take long for many folks to request many cross connects (I myself have already a dozen or so,
|
|
and I'm only one customer in this rack!)
|
|
|
|
One of the advantages of being a launching customer, is that I got to see the rack when it was mostly
|
|
empty. Here we can see Coloclue's switch at the top (with the white flat ribbon RJ45 being my
|
|
interconnect with it). Then there are two PC Engines APUs, which are IP-Max and IPng's OOB serial
|
|
machines. Then comes the ASR9001 called `er01.zrh56.ip-max.net` and under it the Nexus switch that
|
|
IP-Max uses for its local customers (including Coloclue and IPng!).
|
|
|
|
My main router is all the way at the bottom of the picture, called `nlams0.ipng.ch`, one of those
|
|
Supermicro D-1518 machines. It is connected with 2x10G in a LAG to the MPLS switch, and then to most
|
|
of the available internet exchanges in NIKHEF. I also have two transit providers in Amsterdam:
|
|
IP-Max (10Gbit) and A2B Internet (10Gbit).
|
|
|
|
```
|
|
pim@nlams0:~$ birdc show route count
|
|
BIRD v2.15.1-4-g280daed5-x ready.
|
|
10735329 of 10735329 routes for 969311 networks in table master4
|
|
2469998 of 2469998 routes for 203707 networks in table master6
|
|
1852412 of 1852412 routes for 463103 networks in table t_roa4
|
|
438100 of 438100 routes for 109525 networks in table t_roa6
|
|
Total: 15495839 of 15495839 routes for 1745646 networks in 4 tables
|
|
```
|
|
|
|
With the RIB at over 15M entries, I would say this site is very well connected!
|
|
|
|
### Coloclue: Hypervisors
|
|
|
|
I have one Dell R630 at Qupra (`hvn0.nlams1.net.ipng.ch`), one at EUNetworks (`hvn0.nlams2.net.ipng.ch`),
|
|
and a third one with ERITAP at Equinix AM3 (`hvn0.nlams3.net.ipng.ch`). That last one is connected
|
|
with a 10Gbit wavelength to IPng's switch `msw0.nlams0.net.ipng.ch`, and another 10Gbit port to
|
|
FrysIX.
|
|
|
|
{{< image width="350px" float="right" src="/assets/coloclue-ipng/qupra.png" alt="EUNetworks" >}}
|
|
|
|
Arend and I run a small internet exchange called [[FrysIX](https://ixpmanager.frys-ix.net/)]. I
|
|
supply most of the services from that third hypervisor, which has a 10G connection to the local
|
|
FrysIX switch at Equinix AM3. More recently, it became possible to request cross connects at Qupra, so
|
|
I've put in a request to connect my hypervisor there to FrysIX with 10G as well - this will not be
|
|
for peering purposes, but to be able to redundantly connect things like our routeservers,
|
|
ixpmanager, librenms, sflow services, and so on. It's nice to be able to have two hypervisors
|
|
available, as it makes maintenance just that much easier.
|
|
|
|
{{< image width="350px" float="right" src="/assets/coloclue-ipng/eunetworks.png" alt="EUNetworks" >}}
|
|
|
|
Turning my attention to the two hypervisors at Coloclue, one really cool feature that Coloclue
|
|
offers, is an L2 VLAN connection from your colo server to the NIKHEF site over our 10G waves between
|
|
the datacenters. I requested one of these in each site to NIKHEF using Coloclue's VLAN 402 at Qupra,
|
|
and VLAN 412 at EUNetworks. It is over these VLANs that I carry _IPng Site Local_ to the
|
|
hypervisors. I showed this in the overview diagram as an <span
|
|
style='color:orange;font-weight:bold'>orange</span> dashed line. I bridge Coloclue's VLAN 105 (which
|
|
is their eBGP VLAN which has loose uRPF filtering on the Coloclue routers) into a Q-in-Q transport
|
|
towards NIKHEF. These two links are colored <span
|
|
style='color:purple;font-weight:bold'>purple</span> from EUnetworks and <span
|
|
style='color:green;font-weight:bold'>green</span> from Qupra. Finally, I transport my own colocation
|
|
VLAN to each site using another Q-in-Q transport with inner VLAN 100.
|
|
|
|
That may seem overly complicated, so let me describe these one by one:
|
|
|
|
**1. Colocation Connectivity**:
|
|
|
|
I will first create a bridge called `coloclue`, which I'll give an MTU of 1500. I will add to that
|
|
the port that connects to the Coloclue TOR switch, called `eno4`. However, I will give that port an
|
|
MTU of 9216 as I will support jumbo frames on other VLANs later.
|
|
|
|
```
|
|
pim@hvn0-nlams1:~$ sudo ip link add coloclue type bridge
|
|
pim@hvn0-nlams1:~$ sudo ip link set coloclue mtu 1500 up
|
|
pim@hvn0-nlams1:~$ sudo ip link set eno4 mtu 9216 master coloclue up
|
|
pim@hvn0-nlams1:~$ sudo ip addr add 94.142.244.54/24 dev coloclue
|
|
pim@hvn0-nlams1:~$ sudo ip addr add 2a02:898::146:1/64 dev coloclue
|
|
pim@hvn0-nlams1:~$ sudo ip route add default via 94.142.244.254
|
|
pim@hvn0-nlams1:~$ sudo ip route add default via 2a02:898::1
|
|
```
|
|
|
|
**2. IPng Site Local**:
|
|
|
|
All hypervisors at IPng are connected to a private network called _IPng Site Local_ with IPv4
|
|
addresses from `198.19.0.0/16` and IPv6 addresses from `2001:678:d78:500::/56`, both of which are
|
|
not routed on the public Internet. I will give the hypervisor an address and a route towards IPng
|
|
Site local like so:
|
|
|
|
```
|
|
pim@hvn0-nlams1:~$ sudo ip link add ipng-sl type bridge
|
|
pim@hvn0-nlams1:~$ sudo ip link set ipng-sl mtu 9000 up
|
|
pim@hvn0-nlams1:~$ sudo ip link add link eno4 name eno4.402 type vlan id 402
|
|
pim@hvn0-nlams1:~$ sudo ip link set link eno4.402 mtu 9216 master ipng-sl up
|
|
pim@hvn0-nlams1:~$ sudo ip addr add 198.19.4.194/27 dev ipng-sl
|
|
pim@hvn0-nlams1:~$ sudo ip addr add 2001:678:d78:509::2/64 dev ipng-sl
|
|
pim@hvn0-nlams1:~$ sudo ip route add 198.19.0.0/16 via 198.19.4.193
|
|
pim@hvn0-nlams1:~$ sudo ip route add 2001:678:d78:500::/56 via 2001:678:d78:509::1
|
|
```
|
|
|
|
Note the MTU here. While the hypervisor is connected via 1500 bytes to the Coloclue network, it is
|
|
connected with 9000 bytes to IPng Site local. On the other side of VLAN 402 lives the Centec switch,
|
|
which is configured simply with a VLAN interface:
|
|
|
|
```
|
|
interface vlan402
|
|
description Infra: IPng Site Local (Qupra)
|
|
mtu 9000
|
|
ip address 198.19.4.193/27
|
|
ipv6 address 2001:678:d78:509::1/64
|
|
!
|
|
interface vlan301
|
|
description Core: msw0.defra0.net.ipng.ch
|
|
mtu 9028
|
|
label-switching
|
|
ip address 198.19.2.13/31
|
|
ipv6 address 2001:678:d78:501::6:2/112
|
|
ip ospf network point-to-point
|
|
ip ospf cost 73
|
|
ipv6 ospf network point-to-point
|
|
ipv6 ospf cost 73
|
|
ipv6 router ospf area 0
|
|
enable-ldp
|
|
!
|
|
interface vlan303
|
|
description Core: msw0.frggh0.net.ipng.ch
|
|
mtu 9028
|
|
label-switching
|
|
ip address 198.19.2.24/31
|
|
ipv6 address 2001:678:d78:501::c:1/112
|
|
ip ospf network point-to-point
|
|
ip ospf cost 85
|
|
ipv6 ospf network point-to-point
|
|
ipv6 ospf cost 85
|
|
ipv6 router ospf area 0
|
|
enable-ldp
|
|
```
|
|
|
|
There are two other interfaces here: `vlan301` towards the MPLS switch in Frankfurt Equinix FR5 and
|
|
`vlan303` towards the MPLS switch in Lille ETIX#2. I've configured those to enable OSPF, LDP and
|
|
MPLS forwarding. As such, this network with `hvn0.nlams1.net.ipng.ch` becomes a leaf node with a /27 and
|
|
/64 in IPng Site Local, in which I can run virtual machines and stuff.
|
|
|
|
Traceroutes on this private underlay network are very pretty, using the `net.ipng.ch` domain, and
|
|
entirely using silicon-based wirespeed routers with IPv4, IPv6 and MPLS and jumbo frames, never
|
|
hitting the public Internet:
|
|
|
|
```
|
|
pim@hvn0-nlams1:~$ traceroute6 squanchy.net.ipng.ch 9000
|
|
traceroute to squanchy.net.ipng.ch (2001:678:d78:503::4), 30 hops max, 9000 byte packets
|
|
1 msw0.nlams0.net.ipng.ch (2001:678:d78:509::1) 1.116 ms 1.720 ms 2.369 ms
|
|
2 msw0.defra0.net.ipng.ch (2001:678:d78:501::6:1) 7.804 ms 7.812 ms 7.823 ms
|
|
3 msw0.chrma0.net.ipng.ch (2001:678:d78:501::5:1) 12.839 ms 13.498 ms 14.138 ms
|
|
4 msw1.chrma0.net.ipng.ch (2001:678:d78:501::11:2) 12.686 ms 13.363 ms 13.951 ms
|
|
5 msw0.chbtl0.net.ipng.ch (2001:678:d78:501::1) 13.446 ms 13.523 ms 13.683 ms
|
|
6 squanchy.net.ipng.ch (2001:678:d78:503::4) 12.890 ms 12.751 ms 12.767 ms
|
|
```
|
|
|
|
**3. Coloclue BGP uplink**:
|
|
|
|
I make use of the IP transit offering of Coloclue. Coloclue has four routers in total: two in
|
|
EUNetworks and two in Qupra, which I'll show the configuration for here. I don't take the transit
|
|
session on the hypervisor, but rather I forward the traffic Layer2 to my VPP router called
|
|
`nlams0.ipng.ch` over VLAN 402 <span style='color:purple;font-weight:bold'>purple</span> and VLAN
|
|
412 <span style='color:green;font-weight:bold'>green</span> VLANs to NIKHEF. I'll show the
|
|
configuration for Qupra (VLAN 402) first:
|
|
|
|
```
|
|
pim@hvn0-nlams1:~$ sudo ip link add coloclue-bgp type bridge
|
|
pim@hvn0-nlams1:~$ sudo ip link set coloclue-bgp mtu 1500 up
|
|
pim@hvn0-nlams1:~$ sudo ip link add link eno4 name eno4.105 type vlan id 105
|
|
pim@hvn0-nlams1:~$ sudo ip link add link eno4.402 name eno4.402.105 type vlan id 105
|
|
pim@hvn0-nlams1:~$ sudo ip link set eno4.105 mtu 1500 master coloclue-bgp up
|
|
pim@hvn0-nlams1:~$ sudo ip link set eno4.402.105 mtu 1500 master coloclue-bgp up
|
|
```
|
|
|
|
These VLANs terminate on `msw0.nlams0.net.ipng.ch` where I just offer them directly to the VPP
|
|
router:
|
|
|
|
```
|
|
interface eth-0-2
|
|
description Infra: nikhef-core-1.switch.nl.coloclue.net e1/34
|
|
switchport mode trunk
|
|
switchport trunk allowed vlan add 402,412
|
|
switchport trunk allowed vlan remove 1
|
|
lldp disable
|
|
!
|
|
interface eth-0-3
|
|
description Infra: nlams0.ipng.ch:Gi8/0/0
|
|
switchport mode trunk
|
|
switchport trunk allowed vlan add 402,412
|
|
switchport trunk allowed vlan remove 1
|
|
```
|
|
|
|
**4. IPng Services VLANs**:
|
|
|
|
I have one more thing to share. Up until now, the hypervisor has internal connectivity to _IPng Site
|
|
Local_, and a single IPv4 / IPv6 address in the shared colocation network. Almost all VMs at IPng
|
|
run entirely in IPng Site Local, and will use reversed proxies and other tricks to expose themselves
|
|
to the internet. But, I also use a modest amount of IPv4 and IPv6 addresses on the VMs here, for
|
|
example for those NGINX reversed proxies [[ref]({{< ref "2023-03-17-ipng-frontends" >}})], or my
|
|
SMTP relays [[ref]({{< ref "2024-05-17-smtp" >}})].
|
|
|
|
For this purpose, I will need to plumb through some form of colocation VLAN in each site, which
|
|
looks very similar to the BGP uplink VLAN I described previously:
|
|
|
|
```
|
|
pim@hvn0-nlams1:~$ sudo ip link add ipng type bridge
|
|
pim@hvn0-nlams1:~$ sudo ip link set ipng mtu 9000 up
|
|
pim@hvn0-nlams1:~$ sudo ip link add link eno4 name eno4.100 type vlan id 100
|
|
pim@hvn0-nlams1:~$ sudo ip link add link eno4.402 name eno4.402.100 type vlan id 100
|
|
pim@hvn0-nlams1:~$ sudo ip link set eno4.100 mtu 9000 master ipng up
|
|
pim@hvn0-nlams1:~$ sudo ip link set eno4.402.100 mtu 9000 master ipng up
|
|
```
|
|
|
|
Looking at the VPP router, it picks up these two VLANs 402 and 412, which are used for _IPng Site
|
|
Local_. On top of those, the router will add two Q-in-Q VLANs: `402.105` will be the BGP uplink, and
|
|
Q-in-Q `402.100` will be the IPv4 space assigned to IPng:
|
|
|
|
```
|
|
interfaces:
|
|
GigabitEthernet8/0/0:
|
|
device-type: dpdk
|
|
description: 'Infra: msw0.nlams0.ipng.ch:eth-0-3'
|
|
lcp: e0-1
|
|
mac: '3c:ec:ef:46:65:97'
|
|
mtu: 9216
|
|
sub-interfaces:
|
|
402:
|
|
description: 'Infra: VLAN to Qupra'
|
|
lcp: e0-0.402
|
|
mtu: 9000
|
|
412:
|
|
description: 'Infra: VLAN to EUNetworks'
|
|
lcp: e0-0.412
|
|
mtu: 9000
|
|
402100:
|
|
description: 'Infra: hvn0.nlams1.ipng.ch'
|
|
addresses: ['94.142.241.184/32', '2a02:898:146::1/64']
|
|
lcp: e0-0.402.100
|
|
mtu: 9000
|
|
encapsulation:
|
|
dot1q: 402
|
|
exact-match: True
|
|
inner-dot1q: 100
|
|
402105:
|
|
description: 'Transit: Coloclue (urpf-shared-vlan Qupra)'
|
|
addresses: ['185.52.225.34/28', '2a02:898:0:1::146:1/64']
|
|
lcp: e0-0.402.105
|
|
mtu: 1500
|
|
encapsulation:
|
|
dot1q: 402
|
|
exact-match: True
|
|
inner-dot1q: 105
|
|
```
|
|
|
|
Using BGP, my AS8298 will announce my own prefixes and two /29s that I have assigned to me from
|
|
Coloclue. One of them is `94.142.241.184/29` in Qupra, and the other is `94.142.245.80/29` in
|
|
EUNetworks. But, I don't like wasting IP space, so I assign only the first /32 from that range to
|
|
the interface, and use Bird2 to set a route for the other 7 addresses into the interface, which will
|
|
allow me to use all eight addresses!
|
|
|
|
```
|
|
pim@border0-nlams3:~$ traceroute nginx0.nlams1.ipng.ch
|
|
traceroute to nginx0.nlams1.ipng.ch (94.142.241.189), 30 hops max, 60 byte packets
|
|
1 ipmax.nlams0.ipng.ch (46.20.243.177) 1.190 ms 1.102 ms 1.101 ms
|
|
2 speed-ix.coloclue.net (185.1.222.16) 0.448 ms 0.405 ms 0.361 ms
|
|
3 nlams0.ipng.ch (185.52.225.34) 0.461 ms 0.461 ms 0.382 ms
|
|
4 nginx0.nlams1.ipng.ch (94.142.241.189) 1.084 ms 1.042 ms 1.004 ms
|
|
|
|
pim@border0-nlams3:~$ traceroute smtp.nlams2.ipng.ch
|
|
traceroute to smtp.nlams2.ipng.ch (94.142.245.85), 30 hops max, 60 byte packets
|
|
1 ipmax.nlams0.ipng.ch (46.20.243.177) 2.842 ms 2.743 ms 3.264 ms
|
|
2 speed-ix.coloclue.net (185.1.222.16) 0.383 ms 0.338 ms 0.338 ms
|
|
3 nlams0.ipng.ch (185.52.225.34) 0.372 ms 0.365 ms 0.304 ms
|
|
4 smtp.nlams2.ipng.ch (94.142.245.85) 1.042 ms 1.000 ms 0.959 ms
|
|
```
|
|
|
|
### Coloclue: Services
|
|
|
|
I run a bunch of services on these hypervisors. Some are for me personally, or for my company IPng
|
|
Networks GmbH, and some are for community projects. Let me list a few things here:
|
|
|
|
**AS112 Services** \
|
|
I run an anycasted AS112 cluster in all sites where IPng has hypervisor capacity. Notably in
|
|
Amsterdam, my nodes are running on both Qupra and EUNetworks, and connect to LSIX, SpeedIX, FogIXP,
|
|
FrysIX and behind AS8283 and AS8298. The nodes here handle roughly 5kqps at peak, and if RIPE NCC's
|
|
node in Amsterdam goes down, this can go up to 13kqps (right, WEiRD?). I described the setup in an
|
|
[[article]({{< ref "2021-06-28-as112" >}})]. You may be wondering: how do I get those internet
|
|
exchanges backhauled to a VM at Coloclue? The answer is: VxLAN transport! Here's a relevant snippet
|
|
from the `nlams0.ipng.ch` router config:
|
|
|
|
```
|
|
vxlan_tunnels:
|
|
vxlan_tunnel1:
|
|
local: 94.142.241.184
|
|
remote: 94.142.241.187
|
|
vni: 11201
|
|
|
|
interfaces:
|
|
TenGigabitEthernet4/0/0:
|
|
device-type: dpdk
|
|
description: 'Infra: msw0.nlams0:eth-0-9'
|
|
lcp: xe0-0
|
|
mac: '3c:ec:ef:46:68:a8'
|
|
mtu: 9216
|
|
sub-interfaces:
|
|
112:
|
|
description: 'Peering: LSIX for AS112'
|
|
l2xc: vxlan_tunnel1
|
|
mtu: 1522
|
|
vxlan_tunnel1:
|
|
description: 'Infra: AS112 LSIX'
|
|
l2xc: TenGigabitEthernet4/0/0.112
|
|
mtu: 1522
|
|
```
|
|
|
|
And the Centec switch config:
|
|
|
|
```
|
|
vlan database
|
|
vlan 112 name v-lsix-as112 mac learning disable
|
|
interface eth-0-5
|
|
description Infra: LSIX AS112
|
|
switchport access vlan 112
|
|
interface eth-0-9
|
|
description Infra: nlams0.ipng.ch:Te4/0/0
|
|
switchport mode trunk
|
|
switchport trunk allowed vlan add 100,101,110-112,302,311,312,501-503,2604
|
|
switchport trunk allowed vlan remove 1
|
|
```
|
|
|
|
What happens is: LSIX connects the AS112 port to the Centec switch on `eth-0-5`, which offers it
|
|
tagged to `Te4/0/0.112` on the VPP router and without wasting CAM space for the MAC addresses (by
|
|
turing off MAC learning -- this is possible because there's only 2 ports in the VLAN, so the switch
|
|
implicitly always knows where to forward the frames!).
|
|
|
|
After sending it out on `eth-0-9` tagged as VLAN 112, VPP in turn encapsulates it with VxLAN and sends
|
|
it as VNI 11201 to remote endpoint `94.142.241.187`. Because that path has an MTU of 9000, the
|
|
traffic arrives to the VM with 1500b, no worries. Most of my AS112 traffic arrives to a VM this
|
|
way, as it's really easy to flip the remote endpoint of the VxLAN tunnel to anothe replica in case
|
|
of an outage or maintenance. Typically, BGP sessions won't even notice.
|
|
|
|
**NGINX Frontends** \
|
|
At IPng, almost everything runs in the internal network called _IPng Site Local_. I expose this
|
|
network via a few carefully placed NGINX frontends. There are two in my own network (in Geneva and
|
|
Zurich), and one in IP-Max's network (in Zurich), and two at Coloclue (in Amsterdam). They frontend
|
|
and do SSL offloading and TCP loadbalancing for a variety of websites and services. I described the
|
|
architecture and design in an [[article]({{< ref "2023-03-17-ipng-frontends" >}})]. There are
|
|
currently ~120 or so websites frontended on this cluster.
|
|
|
|
**SMTP Relays** \
|
|
I self-host my mail, and I tried to make a fully redundant and self-repairing SMTP in- and outbound
|
|
with Postfix, IMAP server and redundant maildrop storage with Dovecot, a webmail service with
|
|
Roundcube, and so on. Because I need to perform DNSBL lookups, this requires routable IPv4 and IPv6
|
|
addresses. Two of my four mailservers run at Coloclue, which I described in an [[article]({{< ref "2024-05-17-smtp" >}})].
|
|
|
|
**Mailman Service** \
|
|
For FrysIX, FreeIX, and IPng itself, I run a set of mailing lists. The mailman service runs
|
|
partially in IPng Site Local, and has one IPv4 address for outbound e-mail. I separated this from
|
|
the IPng relays so that IP based reputation does not interfere between these two types of
|
|
mailservice.
|
|
|
|
**FrysIX Services** \
|
|
The routeserver `rs2.frys-ix.net`, the authoritative nameserver `ns2.frys-ix.net`, the IXPManager
|
|
and LibreNMS monitoring service all run on hypervisors at either Coloclue (Qupra) or ERITAP
|
|
(Equinix AM3). By the way, remember the part about the enterprise storage? The ixpmanager is
|
|
currently running on `hvn0.nlams3.net.ipng.ch` which has a set of three Samsung EVO consumer SSDs,
|
|
which are really at the end of their life. Please, can I connect to FrysIX from Qupra so I can move
|
|
these VMs to the Seagate SAS-3 MLC storage pool? :)
|
|
|
|
{{< image width="100px" float="right" src="/assets/coloclue-ipng/pencilvester.png" alt="Pencilvester" >}}
|
|
|
|
**IPng OpenBSD Bastion Hosts** \
|
|
IPng Networks has three OpenBSD bastion jumphosts with an open SSH port 22, which are named after
|
|
characters from a TV show called Rick and Morty. **Squanchy** lives in my house on
|
|
`hvn0.chbtl0.net.ipng.ch`, **Glootie** lives at IP-Max on `hvn0.chrma0.net.ipng.ch`, and **Pencilvester**
|
|
lives on a hypervisor at Coloclue on `hvn0.nlams1.net.ipng.ch`. These bastion hosts connect both to the public
|
|
internet, but also to the _IPng Site Local_ network. As such, if I have SSH access, I will also have
|
|
access to the internal network of IPng.
|
|
|
|
**IPng Border Gateways** \
|
|
The internal network of IPng is mostly disconnected from the Internet. Although I can log in via these
|
|
bastion hosts, I also have a set of four so-called _Border Gateways_, which are also connected both
|
|
to the _IPng Site Local_ network, but also to the Internet. Each of them runs an IPv4 and IPv6
|
|
WireGuard endpoint, and I'm pretty much always connected with these. It allows me full access to the
|
|
internal network, and NAT'ed towards the Internet.
|
|
|
|
Each border gateway announces a default route towards the Centec switches, and connect to AS8298,
|
|
AS8283 and AS25091 for internet connectivity. One of them runs in Amsterdam, and I wrote about
|
|
these gateways in an [[article]({{< ref "2023-03-11-mpls-core" >}})].
|
|
|
|
**Public NAT64/DNS64 Gateways** \
|
|
I operate a set of four private NAT64/DNS64 gateways, one of which in Amsterdam. It pairs up and
|
|
complements the WireGuard and NAT44/NAT66 functionality of the _Border Gateways_. Because NAT64 is
|
|
useful in general, I also operate two public NAT64/DNS64 gateways, one at Qupra and one at
|
|
EUNetworks. You can try them for yourself by using the following anycasted resolver:
|
|
`2a02:898:146:64::64` and performing a traceroute to an IPv4 only host, like `github.com`. Note:
|
|
this works from anywhere, but for satefy reasons, I filter some ports like SMTP, NETBIOS and so on,
|
|
roughly the same way a TOR exit router would. I wrote about them in an [[article]({{< ref "2024-05-25-nat64-1" >}})].
|
|
|
|
```
|
|
pim@cons0-nlams0:~$ cat /etc/resolv.conf
|
|
# *** Managed by IPng Ansible ***
|
|
#
|
|
domain ipng.ch
|
|
search net.ipng.ch ipng.ch
|
|
nameserver 2a02:898:146:64::64
|
|
|
|
pim@cons0-nlams0:~$ traceroute6 -q1 ipv4.tlund.se
|
|
traceroute to ipv4c.tlund.se (2a02:898:146:64::c10f:e4c3), 30 hops max, 80 byte packets
|
|
1 2a10:e300:26:48::1 (2a10:e300:26:48::1) 0.221 ms
|
|
2 as8283.ix.frl (2001:7f8:10f::205b:187) 0.443 ms
|
|
3 hvn0.nlams1.ipng.ch (2a02:898::146:1) 0.866 ms
|
|
4 bond0-100.dc5-1.router.nl.coloclue.net (2a02:898:146:64::5e8e:f4fc) 0.900 ms
|
|
5 bond0-130.eunetworks-2.router.nl.coloclue.net (2a02:898:146:64::5e8e:f7f2) 0.920 ms
|
|
6 ams13-peer-1.hundredgige2-3-0.tele2.net (2a02:898:146:64::50f9:d18b) 2.302 ms
|
|
7 ams13-agg-1.bundle-ether4.tele2.net (2a02:898:146:64::5b81:e1e) 22.760 ms
|
|
8 gbg-cagg-1.bundle-ether7.tele2.net (2a02:898:146:64::5b81:ef8) 22.983 ms
|
|
9 bck3-core-1.bundle-ether6.tele2.net (2a02:898:146:64::5b81:c74) 22.295 ms
|
|
10 lba5-core-2.bundle-ether2.tele2.net (2a02:898:146:64::5b81:c2f) 21.951 ms
|
|
11 avk-core-2.bundle-ether9.tele2.net (2a02:898:146:64::5b81:c24) 21.760 ms
|
|
12 avk-cagg-1.bundle-ether4.tele2.net (2a02:898:146:64::5b81:c0d) 22.602 ms
|
|
13 skst123-lgw-2.bundle-ether50.tele2.net (2a02:898:146:64::5b81:e23) 21.553 ms
|
|
14 skst123-pe-1.gigabiteth0-2.tele2.net (2a02:898:146:64::82f4:5045) 21.336 ms
|
|
15 2a02:898:146:64::c10f:e4c3 (2a02:898:146:64::c10f:e4c3) 21.722 ms
|
|
```
|
|
|
|
### Thanks for reading
|
|
|
|
{{< image width="150px" float="left" src="/assets/coloclue-ipng/heart.png" alt="Heart" >}}
|
|
|
|
This article is a bit different to my usual writing - it doesn't deep dive into any protocol or code
|
|
that I've written, but it does describe a good chunk of the way I think about systems and
|
|
networking. I appreciate the opportunities that Coloclue as a networking community and hobby club
|
|
affords. I'm always happy to talk about routing, network- and systems engineering, and the stuff I
|
|
develop at IPng Networks, notably our VPP routing stack. I encourage folks to become a member and
|
|
learn about develop novel approaches to this thing we call the Internet.
|
|
|
|
Oh, and if you're a Coloclue member looking for a secondary location, IPng offers colocation and
|
|
hosting services in Zurich, Geneva, and soon in Lucerne as well :) Houdoe!
|
|
|